Instrument calibration index
Every instrument family the laboratory calibrates, listed by what sits on your bench rather than by measurand: chromatography and spectroscopy, physical property instruments, process equipment and dimensional hand tools.
CALIBRATION / INDEX
By instrument
The metrology pages are organised by what is measured — mass, pressure, temperature, volume. This page is organised by what is sitting on your bench. Every instrument listed here is calibrated in house.
Chromatography and spectroscopy
01 / 06The analytical instruments a testing laboratory’s results stand on. Calibrated across the parameters that actually move a result, not just switched on and checked.
- HPLC and UHPLC
- Flow rate, column oven and autosampler temperature, injection volume, wavelength accuracy, UV detector linearity
- UV-visible spectrophotometer
- Absorbance, transmission, wavelength accuracy
- Atomic absorption spectrophotometer
- Absorbance and linearity
- FTIR spectrometer
- Wave number
- Flame photometer
- Linearity
- Polarimeter
- Angle of rotation
- Karl Fischer titrator
- Delivered volume
Physical property instruments
02 / 06Bench instruments that read a physical property directly, where a drifting scale reads as a real change in the product.
- Brixometer and refractometer
- Brix
- Viscosity meter
- Viscosity
- Hydrometer
- Density
- Lactometer
- Density
- Butyrometer
- Volume
Process and laboratory equipment
03 / 06Equipment whose setting is a control point: if the number on the dial is not the number in the chamber, the process record is wrong.
- Autoclave
- Temperature
- Tachometer and RPM equipment, including centrifuges
- Rotational speed
- Stopwatches, machine timers, HPLC and RPM timers
- Time
Dimensional hand tools
04 / 06The measuring tools on the shop floor rather than in the metrology room — the ones that get dropped, and are rarely checked until something is rejected.
- Vernier calipers
- Length
- Micrometers and screw gauges
- Length
- Height gauges
- Length
- Measuring tapes
- Length
What the certificate carries
05 / 06Every calibration produces a certificate stating the measured value at each point, the deviation from nominal, the uncertainty of measurement, the reference standard used and its traceability, and the environmental conditions the work was done under. As-found data is recorded before any adjustment is made, because as-left data tells you the instrument is fine now and as-found data tells you what your last six months of readings were worth.
Where an instrument is found outside its acceptance criteria it is reported immediately rather than quietly adjusted, so you can assess what was measured on it since its last calibration.
An instrument calibration that reports only a pass has told you almost nothing. The number, its deviation and its uncertainty are the product.
Accredited scope, and everything else
06 / 06This index is a statement of capability, not of accreditation. The laboratory’s accredited calibration scope is defined by the annex to certificate N-C-00592 and by nothing else — it is reproduced line by line on the accreditation page, with the accredited range and CMC for every parameter it covers.
Work outside that annex is done as in-house calibration and is said to be outside the scope before it is commissioned, never after. If your requirement is specifically for accredited calibration, say so at quotation and the reply states plainly whether the instrument falls inside the annex.
At a glance
- Instruments
- 19 families
- Turnaround
- 3–10 working days
- On site
- Non-portable instruments
- Reported
- As-found and as-left
CONTINUE
Where to next
Chemical metrology
pH and conductivity, on the accredited scope. Where the analytical bench instruments report to.
ReadTemperature metrology
Ovens, incubators, chambers, autoclaves and every probe that reads them.
ReadAccreditation and partners
Which of these instruments fall inside the accredited scope, and which are in-house work.