C-15
Chemical reagent preparation, standardisation and management
Preparing solutions that are what the label says, standardising the ones that need it, and controlling the shelf they sit on.
TRAINING / C-15
The course
Preparing solutions that are what the label says, standardising the ones that need it, and controlling the shelf they sit on.
Who it is for
01 / 05Analysts and technicians who prepare reagents and volumetric solutions, and supervisors who review preparation records.
Assumes basic solution chemistry and builds from there into the control and traceability side.
What is covered
02 / 05The syllabus below is the standard shape of the course. It is adjusted to the matrices, methods and instruments you actually run, which is agreed before delivery rather than discovered on the day.
Preparation
Concentration conventions, purity and water-content corrections, grade selection
Water
Grades of laboratory water and where the wrong grade quietly changes a result
Standardisation
Primary standards, titrant standardisation and restandardisation intervals
Labelling
Identity, concentration, preparer, date, expiry, and traceability to the preparation record
Stability
Assigning expiry from evidence rather than convention, and storage conditions
Records
Linking a result back to the specific batch of reagent that produced it
What you leave able to do
03 / 05Courses are written around what a delegate can do afterwards, not what was presented to them. These are the outcomes this one is built to produce.
- Prepare and record a solution so it is traceable back to the materials it came from.
- Standardise a titrant against a primary standard and set a restandardisation interval.
- Assign an expiry date you can justify rather than one that was always used.
- Trace a suspect result back to the reagent batch involved.
Why this course exists
04 / 05The traceability gap here is the one that surfaces during an investigation: a result is questioned, and the laboratory cannot say which batch of titrant produced it because the label carried a date but no link to a preparation record.
Expiry dates set by convention are the other. Six months on everything is not a stability assessment, and it is both wrong and wasteful in different directions for different reagents.
How it is delivered
05 / 05Delivered over 1 day, at your site or at the laboratory, in English or Arabic. Sessions are built around real records, real data and real failures rather than slides of clause numbers, and the people delivering them spend the rest of the week doing the thing being taught.
Group size is agreed in advance — practical sessions are capped so that everyone works rather than watches. An attendance certificate is issued to each delegate on completion.
Ask about any subject not listed here. If it is not something we teach well, we will say so rather than build it for the sake of the booking.
At a glance
- Duration
- 1 day
- Delivered
- On site or at the laboratory
- Language
- English or Arabic
- Certificate
- Attendance certificate issued
CONTINUE
Where to next
Calibration and traceability
What traceability actually requires, how calibration intervals should be set, and how to read a calibration certificate critically.
ReadAnalytical balance
The instrument under almost every result in the laboratory, and the checks that keep it trustworthy between calibrations.
ReadAll courses
The full catalogue, grouped by subject.
ReadRequests are read at the bench.
Send the sample question or the instrument list. It is read by a bench professional, not routed through a ticket queue. Call +966 59 637 8052 or write to lab-mgr@qsinexus.com.