Volumetric glassware: calibration and good laboratory practice
Pipettes, flasks and burettes — what their class actually guarantees, and how to calibrate them gravimetrically when it matters.
TRAINING / C-13
The course
Pipettes, flasks and burettes — what their class actually guarantees, and how to calibrate them gravimetrically when it matters.
Who it is for
01 / 05Analysts and technicians who prepare standards and dilutions, and quality staff who decide which glassware needs in-house calibration.
Covers both glass volumetric ware and piston pipettes, which fail in different ways and are often treated identically.
What is covered
02 / 05The syllabus below is the standard shape of the course. It is adjusted to the matrices, methods and instruments you actually run, which is agreed before delivery rather than discovered on the day.
Classes and tolerances
Class A and B, what the tolerance means, and to-contain versus to-deliver
Gravimetric calibration
Weighing the delivered water and converting via its density
Temperature
Correcting to 20 °C, and the error introduced by ignoring it
Piston pipettes
Accuracy and precision checks, tip fit, technique and pre-wetting
Technique
Meniscus reading, delivery time, drainage and the errors each introduces
Programme
Which items are calibrated, at what interval, and which are simply replaced
What you leave able to do
03 / 05Courses are written around what a delegate can do afterwards, not what was presented to them. These are the outcomes this one is built to produce.
- Calibrate a volumetric item gravimetrically and calculate the corrected volume.
- Decide which glassware in your laboratory warrants calibration and which does not.
- Identify a piston pipette that has drifted before it affects results.
- Correct volumetric technique errors that a tolerance class cannot protect against.
Why this course exists
04 / 05A Class A flask guarantees a tolerance when used correctly at 20 °C. Neither condition is automatically true in a working laboratory, and both are inside the analyst’s control.
Piston pipettes are the bigger exposure. They drift with use, they are used constantly for the most critical volumes, and unlike glass they give no visual sign of being wrong.
How it is delivered
05 / 05Delivered over 1 day, at your site or at the laboratory, in English or Arabic. Sessions are built around real records, real data and real failures rather than slides of clause numbers, and the people delivering them spend the rest of the week doing the thing being taught.
Group size is agreed in advance — practical sessions are capped so that everyone works rather than watches. An attendance certificate is issued to each delegate on completion.
Ask about any subject not listed here. If it is not something we teach well, we will say so rather than build it for the sake of the booking.
At a glance
- Duration
- 1 day
- Delivered
- On site or at the laboratory
- Language
- English or Arabic
- Certificate
- Attendance certificate issued
CONTINUE
Where to next
Calibration and traceability
What traceability actually requires, how calibration intervals should be set, and how to read a calibration certificate critically.
ReadAnalytical balance
The instrument under almost every result in the laboratory, and the checks that keep it trustworthy between calibrations.
ReadAll courses
The full catalogue, grouped by subject.
ReadRequests are read at the bench.
Send the sample question or the instrument list. It is read by a bench professional, not routed through a ticket queue. Call +966 59 637 8052 or write to lab-mgr@qsinexus.com.