GC and GC-MS: operation, troubleshooting and system suitability
Injection through detection, the faults specific to gas chromatography, and what mass spectrometric detection adds and demands.
TRAINING / C-17
The course
Injection through detection, the faults specific to gas chromatography, and what mass spectrometric detection adds and demands.
Who it is for
01 / 05Analysts running GC or GC-MS, and technical staff who review the data. Familiarity with the instrument is assumed.
The GC-MS content covers tuning, identification and confirmation criteria in addition to the chromatographic material.
What is covered
02 / 05The syllabus below is the standard shape of the course. It is adjusted to the matrices, methods and instruments you actually run, which is agreed before delivery rather than discovered on the day.
Injection
Split, splitless and on-column — discrimination and the errors each introduces
Separation
Columns, carrier gas, flow and oven programming
Detectors
FID, ECD and MS — what each sees and what each misses
MS specifics
Tuning, scan versus SIM, spectral matching and confirmation criteria
System suitability
Criteria for GC, and the additional checks MS detection requires
Troubleshooting
Leaks, active sites, retention drift, ghost peaks, contamination and inlet care
What you leave able to do
03 / 05Courses are written around what a delegate can do afterwards, not what was presented to them. These are the outcomes this one is built to produce.
- Choose and set an injection mode appropriate to the analyte and the concentration.
- Diagnose the common GC faults from symptom to cause, starting with the inlet.
- Apply identification and confirmation criteria properly for MS detection.
- Maintain the system so that retention times stay stable across a sequence.
Why this course exists
04 / 05The inlet causes most GC problems and gets the least attention. Discrimination, active sites and leaks all produce results that are quantitatively wrong while looking chromatographically acceptable.
On the MS side the risk is identification confidence — a library match percentage is not a confirmation, and treating it as one is how a wrong compound gets reported with certainty.
How it is delivered
05 / 05Delivered over 2 days, at your site or at the laboratory, in English or Arabic. Sessions are built around real records, real data and real failures rather than slides of clause numbers, and the people delivering them spend the rest of the week doing the thing being taught.
Group size is agreed in advance — practical sessions are capped so that everyone works rather than watches. An attendance certificate is issued to each delegate on completion.
Ask about any subject not listed here. If it is not something we teach well, we will say so rather than build it for the sake of the booking.
At a glance
- Duration
- 2 days
- Delivered
- On site or at the laboratory
- Language
- English or Arabic
- Certificate
- Attendance certificate issued
CONTINUE
Where to next
HPLC and UPLC
Running the instrument well, proving the system was fit before the batch, and diagnosing the faults that produce plausible wrong answers.
ReadUV-visible spectrophotometry
The instrument most laboratories trust most and check least — its performance checks, its linear range, and where Beer’s law stops holding.
ReadAll courses
The full catalogue, grouped by subject.
ReadRequests are read at the bench.
Send the sample question or the instrument list. It is read by a bench professional, not routed through a ticket queue. Call +966 59 637 8052 or write to lab-mgr@qsinexus.com.