C-18
UV-visible spectrophotometry: technical operation and quality control
The instrument most laboratories trust most and check least — its performance checks, its linear range, and where Beer’s law stops holding.
TRAINING / C-18
The course
The instrument most laboratories trust most and check least — its performance checks, its linear range, and where Beer’s law stops holding.
Who it is for
01 / 05Analysts using UV-Vis for quantitative work, and quality staff who write the instrument-check procedures.
Suits both dedicated spectrophotometer users and staff using UV detection as part of another technique.
What is covered
02 / 05The syllabus below is the standard shape of the course. It is adjusted to the matrices, methods and instruments you actually run, which is agreed before delivery rather than discovered on the day.
Principle
Beer’s law, its assumptions, and the concentration at which each one fails
Performance checks
Wavelength accuracy, photometric accuracy, linearity, stray light, noise and baseline flatness
Reference materials
Holmium, potassium dichromate and the certified filters used for each check
Blanks
Choosing the blank that corrects for what actually needs correcting
Calibration curves
Range, weighting, forcing through zero, and honest treatment of outliers
Cuvettes
Material, matching, path length, handling and cleaning
What you leave able to do
03 / 05Courses are written around what a delegate can do afterwards, not what was presented to them. These are the outcomes this one is built to produce.
- Run a full performance check set and judge each result against a criterion.
- Recognise where a sample has left the linear range instead of extrapolating into it.
- Choose a blank that corrects for the interference actually present.
- Build a calibration curve that is defensible, including how outliers were handled.
Why this course exists
04 / 05UV-Vis is simple to operate, which is why it is so often operated without checks. Wavelength drift and stray light both produce smooth, believable, wrong numbers.
Beer’s law failing at high absorbance is the other routine one — a sample read at 2.5 absorbance units is being quantified in a region where the relationship the method depends on has stopped being linear.
How it is delivered
05 / 05Delivered over 1 day, at your site or at the laboratory, in English or Arabic. Sessions are built around real records, real data and real failures rather than slides of clause numbers, and the people delivering them spend the rest of the week doing the thing being taught.
Group size is agreed in advance — practical sessions are capped so that everyone works rather than watches. An attendance certificate is issued to each delegate on completion.
Ask about any subject not listed here. If it is not something we teach well, we will say so rather than build it for the sake of the booking.
At a glance
- Duration
- 1 day
- Delivered
- On site or at the laboratory
- Language
- English or Arabic
- Certificate
- Attendance certificate issued
CONTINUE
Where to next
HPLC and UPLC
Running the instrument well, proving the system was fit before the batch, and diagnosing the faults that produce plausible wrong answers.
ReadGC and GC-MS
Injection through detection, the faults specific to gas chromatography, and what mass spectrometric detection adds and demands.
ReadAll courses
The full catalogue, grouped by subject.
ReadRequests are read at the bench.
Send the sample question or the instrument list. It is read by a bench professional, not routed through a ticket queue. Call +966 59 637 8052 or write to lab-mgr@qsinexus.com.